b2 High Voltage PD120-2 & PDTD120-2 Partial Discharge Diagnostics System
b2 High Voltage · Model PD120-2 / PDTD120-2 · Electrical Test Instruments
120 kV-class partial discharge and combined PD/Tan Delta diagnostics system for cables up to 100 km, rotating machines and transformers.
Key specifications
- Operating voltage (sine): max. 120 kVpeak / 85 kVrms
- PD background level: < 10 pC
- PD localization: 1% accuracy, 0.1 pC per 0.1 m
- Sample rate: 250 MS/s; bandwidth 100 MHz
- Compliance: IEEE 400.2/400.3, IEC 60270, HD 620
Download the PD120-2 / PDTD120-2 datasheet (PDF)
Request a quote from Controware — your authorized b2 High Voltage distributor in the UAE, KSA and Egypt — buy or rent with genuine stock, calibration and technical support.